Breville / Sage Barista Touch error codes
18 codes. The Barista Touch has single ThermoJet heater; most codes are one of its temperature sensors, a water-level or flow fault, or the grinder.
How to read the stored error log
Switch the machine off at the wall. Hold the front Power button, switch the wall power back on and release when the logo appears. Enter the service password 00000, then open Error Counter to see stored faults or Live Debug for live temperatures.
Service menus are intended for technicians. Reading the log is harmless; do not change calibration values.
All codes
| Code | Meaning | Fault | DIY |
|---|---|---|---|
ER01 | Ferro heater temperature sensor open circuit detected at startup | Temperature sensor open circuit (not detected) | moderate |
ER02 | Ferro heater temperature sensor open circuit detected during operation | Temperature sensor open circuit (not detected) | moderate |
ER03 | Ferro heater temperature sensor short circuit detected at startup | Temperature sensor short circuit | moderate |
ER04 | Ferro heater temperature sensor short circuit detected during operation | Temperature sensor short circuit | moderate |
ER05 | Milk jug temperature sensor open circuit detected at startup | Temperature sensor open circuit (not detected) | moderate |
ER06 | Milk jug temperature sensor open circuit detected during operation | Temperature sensor open circuit (not detected) | moderate |
ER07 | Milk jug temperature sensor short circuit detected at startup | Temperature sensor short circuit | moderate |
ER08 | Milk jug temperature sensor short circuit detected during operation | Temperature sensor short circuit | moderate |
ER09 | Inline temperature sensor open circuit detected at startup | Temperature sensor open circuit (not detected) | moderate |
ER10 | Inline temperature sensor open circuit detected during operation | Temperature sensor open circuit (not detected) | moderate |
ER11 | Inline temperature sensor short circuit detected at startup | Temperature sensor short circuit | moderate |
ER12 | Inline temperature sensor short circuit detected during operation | Temperature sensor short circuit | moderate |
ER13 | Flow meter count error detected at startup, indicating a water measurement issue | Flow meter signal problem | moderate |
ER14 | Flow meter count error detected during operation, indicating a water measurement issue | Flow meter signal problem | moderate |
ER15 | Communication fault detected between internal electronic modules | Internal communication fault | moderate |
ER16 | Grinder motor overheated and was shut down for protection | Grinder motor fault | easy |
ER17 | Grinder motor operation timed out before completing its task | Grinder motor fault | easy |
ER18 | E-fast protection triggered due to a detected electrical or safety fault | Electrical safety protection triggered | not recommended |