Breville / Sage Oracle error codes

32 codes. The Oracle has dual stainless boilers plus heated group head; most codes are one of its temperature sensors, a water-level or flow fault, or the grinder.

The Oracle BES980 uses the same 32-code table as the Oracle Touch BES990. On screen it shows "Error 15" rather than "ER15".

How to read the stored error log

Leave the machine plugged in but switched off. Press and hold 1 CUP, 2 CUP and POWER together for at least one second. After the long beep the LCD shows the firmware version (starts with "Fr"). Press the SELECT dial once to open Error Storage, then rotate it to step through errors 1 to 32 and the stored count for each. Scroll past error 32 to "ErSt" and hold SELECT for 3 seconds to clear the log.

Service menus are intended for technicians. Reading the log is harmless; do not change calibration values.

All codes

CodeMeaningFaultDIY
Error rror 1Steam boiler temperature sensor not detected at startupTemperature sensor open circuit (not detected)moderate
Error rror 2Steam boiler temperature sensor lost during operationTemperature sensor open circuit (not detected)moderate
Error rror 3Steam boiler temperature sensor short circuit at startupTemperature sensor short circuitmoderate
Error rror 4Steam boiler temperature sensor short circuit during operationTemperature sensor short circuitmoderate
Error rror 5Coffee boiler temperature sensor not detected at startupTemperature sensor open circuit (not detected)moderate
Error rror 6Coffee boiler temperature sensor lost during operationTemperature sensor open circuit (not detected)moderate
Error rror 7Coffee boiler temperature sensor short circuit at startupTemperature sensor short circuitmoderate
Error rror 8Coffee boiler temperature sensor short circuit during operationTemperature sensor short circuitmoderate
Error rror 9Group head temperature sensor not detected at startupTemperature sensor open circuit (not detected)moderate
Error rror 10Group head temperature sensor lost during operationTemperature sensor open circuit (not detected)moderate
Error rror 11Group head temperature sensor short circuit at startupTemperature sensor short circuitmoderate
Error rror 12Group head temperature sensor short circuit during operationTemperature sensor short circuitmoderate
Error rror 13Steam wand temperature sensor not detected at startupTemperature sensor open circuit (not detected)moderate
Error rror 14Steam wand temperature sensor lost during operationTemperature sensor open circuit (not detected)moderate
Error rror 15Steam wand temperature sensor short circuit at startupTemperature sensor short circuitmoderate
Error rror 16Steam wand temperature sensor short circuit during operationTemperature sensor short circuitmoderate
Error rror 17Coffee boiler not heating up normallyHeater not reaching temperaturehard
Error rror 18Steam boiler not heating up normallyHeater not reaching temperaturehard
Error rror 19Group head not heating up normallyHeater not reaching temperaturehard
Error rror 20Steam boiler water level or pump issue detectedBoiler water level or pump faultmoderate
Error rror 21Steam boiler level probe mismatch detectedBoiler water level or pump faultmoderate
Error rror 22Flow meter signal problem at startupFlow meter signal problemmoderate
Error rror 23Flow meter signal problem during brewingFlow meter signal problemmoderate
Error rror 24Coffee boiler water level probe faultBoiler water level or pump faultmoderate
Error rror 25Coffee boiler overheated above target temperatureOverheated above target temperaturehard
Error rror 26Steam boiler overheated above target temperatureOverheated above target temperaturehard
Error rror 27Group head overheated above target temperatureOverheated above target temperaturehard
Error rror 28Communication fault between control boardsInternal communication faultmoderate
Error rror 29Grinder motor overheatedGrinder motor faulteasy
Error rror 30Grinder motor timed out during operationGrinder motor faulteasy
Error rror 31Tamping motor timed out during operationTamping / dosing motor faulteasy
Error rror 32Steam boiler leak or refill failure detectedSteam boiler leak or refill failuremoderate