CodeFix
ER01Breville

Breville / Sage Barista Touch ER01: temperature sensor open circuit (not detected)

ER01 means: Ferro heater temperature sensor open circuit detected at startup.

Same code, same fix on the Barista Touch Impress. Everything below applies to both.

Applies to: Barista Touch.

Short answerThe control board cannot read the ThermoJet (ferro) heater temperature sensor (NTC). On this code the sensor reads as an open circuit: the wire has come off, the plug is loose or corroded, or the sensor itself has failed. Because it fails the self-test at power-on, the machine refuses to start until the sensor reads again. Breville does not publish this code table, so the meaning comes from third-party service tables.
Part at faultThermoJet (ferro) heater temperature sensor (NTC)
Severitymedium
DIY difficultyhard
When it appearsduring the power-on self-test

How to fix ER01

  1. Switch the machine off at the wall, wait 60 seconds and switch it back on. A one-off reading glitch clears; a real open circuit comes straight back.
  2. Reaching the ThermoJet (ferro) heater temperature sensor (NTC) plug means opening the machine, which is technician work. A technician would check that plug on the control board for corrosion or heat marks and test the sensor circuit. Tell them the code you see.
  3. Look under and around the machine, from the outside, for water trails. Moisture on a connector can read as an open or short circuit; a technician would find and fix the leak behind it, often a boiler o-ring or hose clip.
  4. If the code returns, the ThermoJet (ferro) heater temperature sensor (NTC) or its wiring needs replacing by a technician.
  5. Afterwards, clear the stored error (see how to read the error log below) so you can tell whether it recurs.
Flowchart for fixing ER01: work through each step, stop as soon as the code clearsER01 appears1. Switch the machine off at the wall, wait60 seconds and switch it back on.Fixed?yesDone2. Reaching the ThermoJet (ferro) heatertemperature sensor (NTC) plug means openingthe machine, which is technician work.Fixed?yesDone3. Look under and around the machine, fromthe outside, for water trails.Fixed?yesDone4. If the code returns, the ThermoJet(ferro) heater temperature sensor (NTC) orits wiring needs replacing by a technician.Fixed?yesDone5. Afterwards, clear the stored error (seehow to read the error log below) so you cantell whether it recurs.Still showing?Stop and book service if you see waterleaking, a burning smell or any scorchmarks.
The same steps as the list above, cheapest first. Stop as soon as the code clears.

When to stop and call a repairer

Stop and book service if you see water leaking, a burning smell or any scorch marks. Do not open the machine yourself.

What it costs

PartsNot published by Breville. Ask an authorised service centre for a quote.
ServiceNot published by Breville. Ask an authorised service centre for a quote.
Worth repairing?Often yes for a single sensor, but Breville does not publish repair costs. Get a quote first, especially on an older machine.

How to check the error log

Switch the machine off at the wall. Hold the front Power button, switch the wall power back on and release when the logo appears. Enter the service password 00000, then open Error Counter to see stored faults or Live Debug for live temperatures.

Clear the log after a repair so you can tell whether the fault has really gone.

Beyond the fix

Did you knowNo source ties ER01 to ER04 to a specific part. A general thermocoil guide shows a flat heating element with a centre outlet that sends some water past a temperature sensor.

Tips and tricks

  • Scale lowers flow and brewing temperature, according to the manual. Run the Descale Cycle from Settings with the machine cool and the drip tray empty, and never pull the tank mid-cycle.manufacturer manual
  • If the code returns after a restart and a descale, it needs a qualified technician. They would test the sensor and its wiring and replace the heating element, usually with fresh O-rings and a leak test.technician video
  • Do not open the machine yourself. The manual says to leave anything beyond cleaning to Breville support or an authorized servicer, because these parts sit next to mains wiring.manufacturer manual

Common mistakes

  • Descaling is unlikely to clear an electrical sensor fault, though scale does reduce heat output.

Further reading

Questions

What does ER01 mean on the Breville / Sage Barista Touch?

Ferro heater temperature sensor open circuit detected at startup. The control board cannot read the ThermoJet (ferro) heater temperature sensor (NTC). On this code the sensor reads as an open circuit: the wire has come off, the plug is loose or corroded, or the sensor itself has failed. Because it fails the self-test at power-on, the machine refuses to start until the sensor reads again. Breville does not publish this code table, so the meaning comes from third-party service tables.

Can I fix ER01 myself?

DIY difficulty: hard. Switch the machine off at the wall, wait 60 seconds and switch it back on. A one-off reading glitch clears; a real open circuit comes straight back. Reaching the ThermoJet (ferro) heater temperature sensor (NTC) plug means opening the machine, which is technician work. A technician would check that plug on the control board for corrosion or heat marks and test the sensor circuit. Tell them the code you see.

How much does it cost to fix ER01?

Not published by Breville. Ask an authorised service centre for a quote. Not published by Breville. Ask an authorised service centre for a quote.

Is it worth repairing?

Often yes for a single sensor, but Breville does not publish repair costs. Get a quote first, especially on an older machine.

ER01 during startup or during use?

Breville / Sage Barista Touchs report ER01 during the power-on self-test. That timing is a useful clue when narrowing the cause.

Can I keep using the machine with ER01 showing?

Usually you can finish the drink you are making, but do not ignore it — the underlying fault rarely heals itself. Work through the cheap checks first.

Will ER01 clear on its own?

Rarely. A reset or power cycle is worth one try, but ER01 with a "hard" difficulty rating almost always means a failed component that has to be replaced.

How long does the repair take?

This one is a bench repair for most owners — the teardown, test and reassembly are the bulk of the work, not the part itself.

How reliable is this page?Breville and Sage do not publish a table of error codes for these machines in the documents we found. The meanings on this page come from third-party repair references and owner reports, so treat them as lower confidence. If your machine shows a text alert, follow the on-screen text first. Model revisions can differ: if your machine behaves differently, tell us. See our editorial policy.