CodeFix
Error 10Breville

Breville / Sage Oracle Error 10: temperature sensor open circuit (not detected)

Error 10 means: Group head temperature sensor lost during operation.

The Breville / Sage Oracle shows this code with identical meaning and fix as the Oracle Touch. Full guide for ER10.

Applies to: Oracle.

Short answerThe control board cannot read the group head temperature sensor (NTC). On this code the sensor reads as an open circuit: the wire has come off, the plug is loose or corroded, or the sensor itself has failed. Because it dropped out mid-cycle, a loose or heat-damaged connection is the most likely cause. Breville does not publish this code table, so the meaning comes from third-party service tables.
Part at faultgroup head temperature sensor (NTC)
Severitymedium
DIY difficultyhard
When it appearswhile brewing or steaming

How to fix Error 10

  1. Switch the machine off at the wall, wait 60 seconds and switch it back on. A one-off reading glitch clears; a real open circuit comes straight back.
  2. Reaching the group head temperature sensor (NTC) plug means opening the machine, which is technician work. A technician would check that plug on the control board for corrosion or heat marks and test the sensor circuit. Tell them the code you see.
  3. Look under and around the machine, from the outside, for water trails. Moisture on a connector can read as an open or short circuit; a technician would find and fix the leak behind it, often a boiler o-ring or hose clip.
  4. If the code returns, the group head temperature sensor (NTC) or its wiring needs replacing by a technician.
  5. Afterwards, clear the stored error (see how to read the error log below) so you can tell whether it recurs.
Flowchart for fixing Error 10: work through each step, stop as soon as the code clearsError 10 appears1. Switch the machine off at the wall, wait60 seconds and switch it back on.Fixed?yesDone2. Reaching the group head temperaturesensor (NTC) plug means opening the machine,which is technician work.Fixed?yesDone3. Look under and around the machine, fromthe outside, for water trails.Fixed?yesDone4. If the code returns, the group headtemperature sensor (NTC) or its wiring needsreplacing by a technician.Fixed?yesDone5. Afterwards, clear the stored error (seehow to read the error log below) so you cantell whether it recurs.Still showing?Stop and book service if you see waterleaking, a burning smell or any scorchmarks.
The same steps as the list above, cheapest first. Stop as soon as the code clears.

When to stop and call a repairer

Stop and book service if you see water leaking, a burning smell or any scorch marks. Do not open the machine yourself.

What it costs

PartsNot published by Breville. Ask an authorised service centre for a quote.
ServiceNot published by Breville. Ask an authorised service centre for a quote.
Worth repairing?Often yes for a single sensor, but Breville does not publish repair costs. Get a quote first, especially on an older machine.

How to check the error log

Leave the machine plugged in but switched off. Press and hold 1 CUP, 2 CUP and POWER together for at least one second. After the long beep the LCD shows the firmware version (starts with "Fr"). Press the SELECT dial once to open Error Storage, then rotate it to step through errors 1 to 32 and the stored count for each. Scroll past error 32 to "ErSt" and hold SELECT for 3 seconds to clear the log.

Clear the log after a repair so you can tell whether the fault has really gone.

Beyond the fix

Did you knowBreville describes the Oracle Touch group head as actively heated by an embedded element, so a fault there can affect shot temperature without any change to the boilers.

Tips and tricks

  • Before inserting the portafilter, run water through the group head for about 5 seconds. This clears coffee residue and settles the water temperature before a shot.manufacturer manual
  • Do the clear-water backflush with the cleaning disc before switching off: build pressure for 20 seconds, release, repeat 5 times. It purges coffee oils and fines from the brew water path.manufacturer manual
  • A technician video shows entering the service menu by holding the power button while plugging in; the method varies by machine build year. Note the stored errors, clear them and restart to see which return.technician video

Common mistakes

  • Clearing or ignoring the stored error without noting which code and how often it appeared, which loses the best clue for a technician.
  • Assuming one forum fix applies to every ER code. The same word-for-word code on a Barista Touch can point to a different part.

Easily confused with

  • An on-screen Operation Error message is a generic fault notice in the manual, not one of these numbered codes. Check the service menu for the stored number.

Further reading

Questions

What does Error 10 mean on the Breville / Sage Oracle?

Group head temperature sensor lost during operation. The control board cannot read the group head temperature sensor (NTC). On this code the sensor reads as an open circuit: the wire has come off, the plug is loose or corroded, or the sensor itself has failed. Because it dropped out mid-cycle, a loose or heat-damaged connection is the most likely cause. Breville does not publish this code table, so the meaning comes from third-party service tables.

Can I fix Error 10 myself?

DIY difficulty: hard. Switch the machine off at the wall, wait 60 seconds and switch it back on. A one-off reading glitch clears; a real open circuit comes straight back. Reaching the group head temperature sensor (NTC) plug means opening the machine, which is technician work. A technician would check that plug on the control board for corrosion or heat marks and test the sensor circuit. Tell them the code you see.

How much does it cost to fix Error 10?

Not published by Breville. Ask an authorised service centre for a quote. Not published by Breville. Ask an authorised service centre for a quote.

Is it worth repairing?

Often yes for a single sensor, but Breville does not publish repair costs. Get a quote first, especially on an older machine.

When does Error 10 typically show up?

Breville / Sage Oracles report Error 10 while brewing or steaming. That timing is a useful clue when narrowing the cause.

Can I keep using the machine with Error 10 showing?

Usually you can finish the drink you are making, but do not ignore it — the underlying fault rarely heals itself. Work through the cheap checks first.

Will Error 10 clear on its own?

Rarely. A reset or power cycle is worth one try, but Error 10 with a "hard" difficulty rating almost always means a failed component that has to be replaced.

How long does the repair take?

This one is a bench repair for most owners — the teardown, test and reassembly are the bulk of the work, not the part itself.

How reliable is this page?Breville and Sage do not publish a table of error codes for these machines in the documents we found. The meanings on this page come from third-party repair references and owner reports, so treat them as lower confidence. If your machine shows a text alert, follow the on-screen text first. Model revisions can differ: if your machine behaves differently, tell us. See our editorial policy.