Breville / Sage Oracle Touch error codes

32 codes. The Oracle Touch has dual stainless boilers plus heated group head; most codes are one of its temperature sensors, a water-level or flow fault, or the grinder.

How to read the stored error log

Switch the machine off at the wall. Hold the front Power button, switch the wall power back on and release when the logo appears. Enter the service password 00000, then open Error Counter (stored faults) or Live Debug (live temperatures and water levels). One technician video says the entry method differs between machines built before and after 2018, so if this does not work, do not keep trying.

Service menus are intended for technicians. Reading the log is harmless; do not change calibration values.

All codes

CodeMeaningFaultDIY
ER01Steam boiler temperature sensor not detected at startupTemperature sensor open circuit (not detected)hard
ER02Steam boiler temperature sensor lost during operationTemperature sensor open circuit (not detected)hard
ER03Steam boiler temperature sensor short circuit at startupTemperature sensor short circuithard
ER04Steam boiler temperature sensor short circuit during operationTemperature sensor short circuithard
ER05Coffee boiler temperature sensor not detected at startupTemperature sensor open circuit (not detected)hard
ER06Coffee boiler temperature sensor lost during operationTemperature sensor open circuit (not detected)hard
ER07Coffee boiler temperature sensor short circuit at startupTemperature sensor short circuithard
ER08Coffee boiler temperature sensor short circuit during operationTemperature sensor short circuithard
ER09Group head temperature sensor not detected at startupTemperature sensor open circuit (not detected)hard
ER10Group head temperature sensor lost during operationTemperature sensor open circuit (not detected)hard
ER11Group head temperature sensor short circuit at startupTemperature sensor short circuithard
ER12Group head temperature sensor short circuit during operationTemperature sensor short circuithard
ER13Steam wand temperature sensor not detected at startupTemperature sensor open circuit (not detected)hard
ER14Steam wand temperature sensor lost during operationTemperature sensor open circuit (not detected)hard
ER15Steam wand temperature sensor short circuit at startupTemperature sensor short circuithard
ER16Steam wand temperature sensor short circuit during operationTemperature sensor short circuithard
ER17Coffee boiler temperature not rising as expectedHeater not reaching temperaturenot recommended
ER18Steam boiler temperature not rising as expectedHeater not reaching temperaturenot recommended
ER19Group head temperature not rising as expectedHeater not reaching temperaturenot recommended
ER20Steam boiler water level or pump issue detectedBoiler water level or pump faulthard
ER21Steam boiler high level probe fault detectedBoiler water level or pump faulthard
ER22Flow meter signal problem at startupFlow meter signal problemmoderate
ER23Flow meter signal problem during brewingFlow meter signal problemmoderate
ER24Coffee boiler level probe fault (unconfirmed; probes are documented on the steam boiler)Boiler water level or pump faulthard
ER25Coffee boiler overheated above target temperatureOverheated above target temperaturehard
ER26Steam boiler overheated above target temperatureOverheated above target temperaturehard
ER27Group head overheated above target temperatureOverheated above target temperaturehard
ER28Communication fault between control boardsInternal communication faultnot recommended
ER29Grinder motor overheatedGrinder motor faulteasy
ER30Grinder motor timed out during operationGrinder motor faulteasy
ER31Tamping motor timed out during operationTamping / dosing motor faulteasy
ER32Steam boiler leak or refill failure detectedSteam boiler leak or refill failurehard

Other Breville / Sage machines